Back to Product Guide - Frequency/Rate/Total/Timer/Batch

SPECIFICATIONS


TIME BASE
Internal clock reference: 11.059 MHz crystal oscillator
Nominal gate time: Programmable from 0.00 s to 99.99 s in 10 ms steps
Calibration accuracy at 25°C: ±2 ppm
Temperature stability, 0-60°C: ±50 ppm over entire range
Long-term drift: ±2 ppm/month
Fine-calibration method: External standard and correction multiplier

SIGNAL CONDITIONERS

0. TTL-LEVEL PULSE INPUT (STD)
Common Specs
Threshold:
0.8 V LO, 2.0 V HI
Frequency ranges: 0-3 kHz, 0-100 kHz, 0-7 MHz
Protection level: ­20 to +25 V in 3 kHz & 100 kHz ranges
Trigger slope: + or ­ (programmable)

TTL-level logic input
Connection:
2-wire

Form-C contact-closure
Connection:
3-wires plus external 20 k resistor
Debounce: Internal flip-flop

NPN or PNP open-collector
Connection:
3-wire
Sensor excitation: +5 V

1 & 2. ISOLATED PULSE INPUT WITH EXCITATION (OPT)

Voltage input & passive magnetic pickup
Maximum signal:
260 V rms
Sensitivity (square-wave input): ±10 mV, 0 to 1 kHz; ±25 mV at 20 kHz; ±50 mV at 100 kHz
Input impedance: 1 M, signal < ±500 mV
> 70 k, signal > ±500 mV
Hysteresis: 12, 70, 700 mV (jumper-selectable)

NPN or PNP open-collector input
Connection:
3-wire
Sensor excitation output: 12.4 V at 20 mA
Internal load (jumper-selectable): 1 k pull-up resistor to +8.2 V (NPN mode) / 3 k pull-down resistor to EXC LO (PNP mode)
Switching threshold: 4.2 to 8.2 V (adjustable)

NAMUR input
Connection:
2-wire
Sensor excitation output: 8.2 V
Internal load/source impedance: 1 k
Activated: < 1 mA
Deactivated: > 3 mA

Contact-closure input
Connection:
2-wire
Sensor excitation output: 6.2 V, 1M source
Switching threshold: 0 to +2.0 V (adjustable)
Debounce time: 0, 1, 22, 120 ms (jumper-selectable)
Minimum OFF period: 8 or 100 ms (jumper-selectable)

Common specs, all input types
Number of channels:
1 or 2
Common-mode voltage (CMV): 350 Vp
Frequency range: DC input: 0 to 100 kHz and AC-coupled input: 2 Hz to 100 kHz
Low-pass filter: 65 Hz, 1 kHz, 100 kHz (jumper-selectable)
Trigger slope: + or ­ (programmable)

3. NON-ISOLATED PULSE INPUT W/EXCITATION (OPT)
Common specs
Number of channels:
1
Frequency response: 10 kHz

Voltage input & passive magnetic pickup
Minimum signal, valley to crest:
0 to 120 mV
Maximum signal: 60 V rms
Input impedance: 160 kOhm

NPN open-collector input
Connection:
3-wire
Sensor excitation output: 16 V at 25 mA or 20 V at 16 mA (jumper-selectable)
Internal load: 7.5 k pull-up resistor to +5 V dc

NAMUR input
Connection: 2-wire
Sensor excitation output: 8.2 V
Internal load/source impedance: 1 k
Activated: < 1 mA
Deactivated: > 3 mA

Contact-closure input
Connection:
2-wire
Debounce time: 15 µs, 10 ms or 80 ms (jumper-selectable)

4. ANALOG INPUT (OPT)
Number of channels:
1
Isolation, SIG GND to DIG GND: 350 Vp
Signal range: 0-1 mA, 4-20 mA, 0-5 V, 1-5 V, 0-10 V dc (jumper-selectable)
Output to main meter: 1 Hz to 10 kHz
Low-level shutoff: Jumper selection to disable output below 10 Hz, 50 Hz or 260 Hz
Zero offset adjustment: ±5% of full scale via potentiometer
Non-linearity, max: ±.02% of full scale
Accuracy at 25°C: 99.95% of reading
Tempco of span: ±0.005% of reading/°C (50 ppm/°C) in 4-20 mA range
Tempco offset: 0.1 count/°C